Sign In | Join Free | My himfr.com
Home > Environmental Testing Machine >

Simulated High Altitude And Low Pressure Test Chamber For Battery Vacuum Degree 40Kpa (7200 Meters) AC 220V 50HZ HZ-2014D

    Buy cheap Simulated High Altitude And Low Pressure Test Chamber For Battery Vacuum Degree 40Kpa (7200 Meters) AC 220V 50HZ HZ-2014D from wholesalers
     
    Buy cheap Simulated High Altitude And Low Pressure Test Chamber For Battery Vacuum Degree 40Kpa (7200 Meters) AC 220V 50HZ HZ-2014D from wholesalers
    • Buy cheap Simulated High Altitude And Low Pressure Test Chamber For Battery Vacuum Degree 40Kpa (7200 Meters) AC 220V 50HZ HZ-2014D from wholesalers
    • Buy cheap Simulated High Altitude And Low Pressure Test Chamber For Battery Vacuum Degree 40Kpa (7200 Meters) AC 220V 50HZ HZ-2014D from wholesalers
    • Buy cheap Simulated High Altitude And Low Pressure Test Chamber For Battery Vacuum Degree 40Kpa (7200 Meters) AC 220V 50HZ HZ-2014D from wholesalers

    Simulated High Altitude And Low Pressure Test Chamber For Battery Vacuum Degree 40Kpa (7200 Meters) AC 220V 50HZ HZ-2014D

    Ask Lasest Price
    Brand Name : lixian
    Model Number : HZ-2014D
    Certification : CE
    Price : negotiate
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : negotiate
    Delivery Time : 7 days
    • Product Details
    • Company Profile

    Simulated High Altitude And Low Pressure Test Chamber For Battery Vacuum Degree 40Kpa (7200 Meters) AC 220V 50HZ HZ-2014D

    Simulated High Altitude And Low Pressure Test Chamber For Battery Vacuum Degree 40Kpa (7200 Meters) AC 220V 50HZ HZ-2014D

    Simulated High Altitude and Low Pressure Test cham...

    Low Pressure Test Chamber Equipment summary

    Battery low-voltage (high altitude) simulation test, all tested samples are tested under a negative pressure of 11.6kPa (1.68psi). The final result of the test requires that the battery cannot explode or catch fire. In addition, the battery must not smoke or leak. The battery protection valve cannot be destroyed.


    Low Pressure Test Chamber Main features and functions

    The inner box of the box is made of high-quality SUS201# stainless steel plate material. The studio is made of high-quality steel plate with rounded corners, smooth, smooth and easy to clean. The front door of the test chamber adopts a reinforced design. The left side of the door is equipped with anexposedhinge and the right side is equipped with a powerful door lock to effectively seal the door. The hinges and locks usereinforced equipment-specific standard parts. There are 6 casters at the bottom and foot cups for easy movement and fixation. This machine adopts PLC touch screen control system, which is convenient and intuitive, and can easily control eachinput test parameter. A rubber sealing ring is installed between the working room and the door to ensure a high degree of vacuuminthebox;Integrated: the low-pressure box is at the bottom and the vacuum pump is at the rear; The vacuum value can be automatically set and the vacuum can be replenished automatically.


    Low Pressure Test Chamber Comply with standards

    GB 31241-2022 "Safety Requirements for Lithium-Ion Cells and Battery Packs for Portable Electronic Products"

    YDT 2344.1-2011 Universal lithium iron phosphate battery pack Part 1: Integrated battery pack.

    standard requirement: After the battery is fully charged according to the prescribed test method, place the battery in a vacuumbox at 25±5°C,evacuate to reduce the pressure in the box to 40kPa (simulated altitude 7200m), and maintain it for 6 hours. Acceptance criteria: The battery should not catch fire, explode, or leak, and the voltage drop should not exceed10%.

    standard requirement: After the battery is fully charged according to the prescribed test method, place the battery in a vacuumbox at 20°C±5°C, evacuate to reduce the pressure in the box to 40kPa (simulated altitude of 7200m), and maintain it for 6hours. Acceptance criteria: The battery should not catch fire, explode, or leak.


    Low Pressure Test Chamber Technical principles

    1. The vacuum chamber is required to be a completely sealed container, round or square;

    2. Principle of vacuuming: Connect a pipe from the completely sealed vacuum chamber, pass through the manual valveor solenoid, and then connect it to the air extraction port of the vacuum pump; when the required vacuumdegreeisreached, stop the vacuum pump and close the manual valve or solenoid at the same time. valve to maintainacertaindegree of vacuum in the box; at the same time, a vacuum gauge is installed to display the vacuumdegree;

    3. After starting the vacuum pump, the vacuum pump will compress the air in the completely sealed container sothatthe pressure in the container is lower than the ambient pressure. It will be discharged to the environment throughtheexhaust port and all the air in the container will be removed to achieve the vacuum effect; negative The lower thepressure, the higher the vacuum;

    4. When the air in the box is completely restored, start the inflation function to fill the box with ambient air. Whenthepressure is the same as the ambient pressure, it is completely restored;

    5. Carry out vacuum test using this cycle


    Low Pressure Test Chamber Technical Parameters

    ModelHZ-Z-2014D
    temperature rangeNormal temperature 25±5℃
    Display methodtouchscreen
    Vacuum degree40Kpa (7200 meters)
    control precision±0.2Kpa
    Adjustment range1 ~ -95Kpa (negative pressure gauge)
    unitKpa
    time limit99H59M59S (can be set)
    vacuum time≤6/M
    Maintaining pressure leakage rate≤2.0Kpa
    Pressure relief time≤5/M
    power supplyAC 220V10% 50HZ
    Power3.5.KW
    Machine weightAbout 1000KG


    Quality Simulated High Altitude And Low Pressure Test Chamber For Battery Vacuum Degree 40Kpa (7200 Meters) AC 220V 50HZ HZ-2014D for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Dongguan Lixian Instrument Scientific Co.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)